Page 11 - WEB-I3 Insulating Glass Fabrication Supplies and Equipment
P. 11

FHC INSULATING GLASS FABRICATION, SUPPLIES, AND EQUIPMENT                                     SECTION 2
                                                                                                            SECTION 2
              FHC IG Fabrication Methods               Bulk Quantities Available
                                                        Click to Chat With Us


             FHC Silicone

             Foam Super

             Spacer  Notcher
                               ®


                - Hand-Held Pneumatic Tool for a Continuous Process
                -  Space Width Adjustment Can Accommodate
              Sizes from 3/16" to 15/16"
                -  Fixed Setback Distance for
              Straight-Line Application
                - Circular Punch for Corner Notching
                -  Cutting Blade or Final Spacer Cut-Off

                                                                                                ITEM NO. QSSPN1
                                                                                                 Pneumatic Notcher




              1.  Once the liner is stripped from the Super Spacer, with the foil   6.  Glide the tool along the glass edge until the next corner is
               surface facing the operator, insert spacer into the notcher   reached. Press the notcher punch trigger to activate the
               shuttle tool between the pressure wheel and the guide roller   notcher punch
              2.  To load, pull the spacer through so that it extends beyond the   7.  Continue moving the tool straight ahead until the left side of the

                pressure wheel and parallel to the base of the tool. Once the   notch is aligned with back edge of the faceplate. Press down on
                cutting blade is engaged and you’re ready to notch a corner,   the spacer to ensure good adhesion
                activate the punch trigger
                                                                  8.  Tack down spacer at about 1" distance from the corner. Proceed
              3.  Position the spacer so that the bottom spacer edge exceeds the   with spacer application, repeating steps at the second and
                tool base by about 1/32"                            third corner
              4.  Place the guide block against the side of the first glass lite and   9.  At a point approximately 1" from the final corner, guide the tool
                align with the starting corner of the glass. Once aligned, tack   slightly outward to avoid hitting the starting end of the spacer.
                down by applying pressure                           Notch and cut off the spacer end and remove tool by pulling it
                                                                    forward and off the previously applied spacer
              5.  Support the spacer tape slightly above the glass surface. While
                maintaining the tape perpendicular to the glass, apply slight   10 Manually align the spacer ends to form the final corner joint
                downward pressure and glide the tool along the glass edge
                toward the second corner                          For videos and the complete instructions visit fhc-usa.com.



                                                                                           ATTENTION: The FHC Super
                                                                                           Spacer  contains a desiccant
                                                                                                ®
              A.             B.             C.                                             and must not be left out in
               CORNER         CORNER                                                       the open air for any duration.
               CUT-OUT        CUT-OUT
                       GLASS         GLASS          GLASS
                                                                                           Ensure that any material not
                                                                                           immediately used is repacked in
                      SPACER         SPACER         SPACER
                                                                                           the provided foil bag and then
                                                                                           securely stored in a Ziplock bag
                           Typical Corner Notch                                            or a similar container that is
                                                                                           hermetically sealed.
                                                                         Finished Corner
               Super Spacer is a registered trademark of Quanex Building Products Corp.
               V
               Visit fhc-usa.com to search for
                      com
                         to search f
                              or
                isit
                  f
                  hc-usa.
               Keyword                                        FRAMELESS HARDWARE COMPANY LLC
               Super Spacer
                                                           4361 Firestone Blvd. South Gate, CA 90280
               Enter the Item Number or scan QR code with      Toll Free: (888) 295-4531  |  Direct: (323) 968-2031
               Enter the Item Number or scan QR code with
               our smar
               your smartphone for complete product details                                                       IG11
               y
                         or comple
                              te produc
                    tphone f
                                   t de
                                     tails
                                                                Fax: (323) 336-8307  |  fhc-usa.com
   6   7   8   9   10   11   12   13   14   15   16